Politiv’s laboratory has been certified and duly authorized since 1997 in accordance with ASTM and International Standard ISO-9001:2008
Our company is highly invested in quality control. As part of this effort A.A. Politiv has set up one of the most sophisticated polyethylene film testing laboratories in the world.
Our laboratory is operated by a team of highly skilled personnel who have been specifically trained in quality control. The team maintains ongoing relationships with external laboratories from all over the world and updates its techniques accordingly.
A.A. Politiv has established a meticulous and uncompromising approach towards the quality of its products; guided by a constant goal always to meet the needs of distributors and growers around the world.
A.A. Politiv products meet the most strict standards in the world. Click here to read more about A.A. Politiv's standards.
|
Q.A. Lab
|
Ahed Watted
Technical Manager
|
Osnat Yahalom
Q.A. Manager
|
Yafa Amitai
Q.A. Inspector
|
Nitsan Sommer
Q.A. Inspector
|
Svatlana Pichhadza
Q.A. Inspector
|
|
Laboratory Equipment:
(Click image to enlarge it or Emphasized words to learn more) |
|
Digital Micrometer:
A precise gauging method. The digital micrometer is used to measure the average thickness of the film and the thickness deviations (maximum, minimum and STD). The measurements are carried each 5-7 cm widthwise the film. At the end of the measurements, the data is printed.
|
|
FTIR Device:
This method is used to analyze the UV stabilizers type and percentage in the film. Also, the FTIR is used to measure the film thermicity according to the local and international standards.
|
|
UV-VIS Device:
The UV-VIS is used to measure the total light transmission in PAR range (400-700nm) and the total light diffusion. Also, the UV-VIS is used to measure the UV light blocking in Anti-Virus films.
This device used for testing the light transmission, in both the visible spectrum and the ultra violet (UV) range. Also, It is used for testing the blocking of the UV range (anti virus sheets).
|
|
Elongation and Strength extensometer:
The Extensometer is used to measure the maximum load need to film break and the film strain at break. The specimens dimensions, test conditions and test procedure are according the international standards (ASTM, ISO). Our standard for all films is minimum 20MPa for Tensile at brake and 500% for the film strain (Elongation) at brake.
|
|
Dart Falling Impact:
This method is used to determine the energy that cause film fail under specified conditions. This energy is expressed in term of weight of the missile falling from specified high. The test is carried according to ASTM D1709-85.
|
|
QUV:
The QUV device is used to test the films durability. It includes lamps that emit an aggressive radiation in the ultra violet range (UV range), to simulating sun exposure in a short time.
|
|
ASH content:
Ash test is used to identify the total filler (White pigment, black pigment and diffusers) content in the film.
Ash test involves taking a known amount of sample, burning away the polymer in an air atmosphere at temperatures above 500°C, and weighing the crucible after it has been cooled to room temperature in desiccators.
|
|
Anti-fog tests chamber:
An accelerated anti-fog (anti-drip) tests greenhouse. Mainly used for R&D application for testing a new anti-fog additives and developing a long term anti-fog properties. The chamber contains a hot water bath in 500C to provide a very aggressive condition and to force the Anti-fog to "work" continuously.
|
|
Anti-fog Q.C. tests:
Test Method: To pour 60°C water in to a beaker and cover with Antifog PE Film. Record the change in film appearance. Clear film for excellent anti-fog performance and opaque small drops means for bad anti-fog performance.
|
|
Kündig: